dc.contributor.authorZapata Arráez, Félix 
dc.contributor.authorOrtega Ojeda, Fernando Ernesto 
dc.contributor.authorGarcía Ruiz, Carmen 
dc.contributor.authorGonzález Herráez, Miguel 
dc.date.accessioned2018-09-05T11:33:15Z
dc.date.available2018-09-05T11:33:15Z
dc.date.issued2018-07-08
dc.identifier.bibliographicCitationZapata, F., Ortega-Ojeda, F., García-Ruiz, C., González-Herráez, M. Selective monitoring of oxyanion mixtures by a flow system with Raman detection (2018) Sensors (Switzerland), 18 (7), art. no. 2196en
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10017/34200
dc.description.abstractRaman spectroscopy is a selective detection system scarcely applied for the flow analysis of solutions with the aim of detecting several compounds at once without a previous separation step. This work explores the potential of a portable Raman system in a flow system for the selective detection of a mixture of seven oxyanions (carbonate, sulphate, nitrate, phosphate, chlorate, perchlorate, and thiosulphate). The specific bands of these compounds (symmetric stretching Raman active vibrations of carbonate at 1068 cm−1, nitrate at 1049 cm−1, thiosulphate at 998 cm−1, phosphate at 989 cm−1, sulphate at 982 cm−1, perchlorate at 935 cm−1, and chlorate at 932 cm−1) enabled their simultaneous detection in mixtures. Although the oxyanions’ limit of detection (LOD) was rather poor (in the millimolar range), this extremely simple system is very useful for the single-measurement detection of most of the oxyanions in mixtures, without requiring a previous separation step. In addition, quantitative determination of the desired oxyanion can be performed by means of the corresponding calibration line. These are important advantages for controlling in-line processes in industries like those manufacturing fertilizers, pharmaceuticals, chemicals, or food, among others.en
dc.description.sponsorshipMinisterio de Educación y Cienciaes_ES
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherMDPI
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectFlow analysisen
dc.subjectOxyanionsen
dc.subjectRaman detectionen
dc.titleSelective monitoring of oxyanion mixtures by a flow system with Raman detectionen
dc.typeinfo:eu-repo/semantics/articleen
dc.subject.ecienciaCiencias tecnológicases_ES
dc.subject.ecienciaElectrónicaes_ES
dc.subject.ecienciaTechnologyen
dc.subject.ecienciaElectronicsen
dc.contributor.affiliationUniversidad de Alcalá. Departamento de Electrónicaes_ES
dc.relation.publisherversionhttps://doi.org/10.3390/s18072196
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.3390/s18072196
dc.relation.projectIDinfo:eu-repo/grantAgreement/MEC//FPU14%2F00790/ESes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen
dc.identifier.publicationtitleSensors