Brillouin optical time-domain analysis assisted by second-order Raman amplification
Autores
Martín López, Sonia; Alcón-Camas, M.; Rodríguez, F.; Corredera, Pedro; Ania Castañón, Juan Diego; [et al.]Identificadores
Enlace permanente (URI): http://hdl.handle.net/10017/28619DOI: 10.1364/OE.18.018769
ISSN: 1094-4087
Editor
Optical Society of America
Fecha de publicación
2010-08-30Patrocinadores
Ministerio de Ciencia e Innovación
Ministerio de Fomento
Comunidad de Madrid
Cita bibliográfica
Martin-Lopez, S., Alcon-Camas, M., Rodriguez, F., Corredera, P., Ania-Castañon, J.D., Thévenaz, L., Gonzalez-Herraez, M., 2010, "Brillouin optical time-domain analysis assisted by second-order Raman amplification, Optics Express, 18 , n. 18, pp. 18769-18778.
Palabras clave
Nonlinear optics
Fibers
Scattering
Stimulated Brillouin
Propagation
Proyectos
info:eu-repo/grantAgreement/MICINN//TEC2008-05791/ES/NUEVAS APLICACIONES DEL EFECTO RAMAN EN FIBRA OPTICA Y LASERES ULTRALARGOS/
info:eu-repo/grantAgreement/MICINN//TEC2009-14423-C02-01/ES/Aplicacion Del Laser Femto Fibre Comb A La Metrologia De Frecuencias Para Comunicaciones Opticas/
info:eu-repo/grantAgreement/MICINN//TEC2009-14423-C02-02/ES/Aplicacion Del Laser Femtocomb Al Estudio De Estructuras Semiconductoras Para Comunicaciones Opticas/
info:eu-repo/grantAgreement/MIFFO//FOM-07%2F77/ES//
info:eu-repo/grantAgreement/CAM//S2009%2FESP1781/ES//FACTOTEM2
Tipo de documento
info:eu-repo/semantics/article
Versión
info:eu-repo/semantics/acceptedVersion
Versión del editor
http://dx.doi.org/10.1364/OE.18.018769Derechos de acceso
info:eu-repo/semantics/openAccess
Resumen
We propose and experimentally demonstrate a new method to
extend the range of Brillouin optical time domain analysis (BOTDA)
systems. It exploits the virtual transparency created by second-order Raman
pumping in optical fibers. The idea is theoretically analyzed and
experimentally demonstrated in a 50 km fiber. By working close to
transparency, we also show that the measurement length of the BOTDA
can be increased up to 100 km with 2 meter resolution. We envisage
extensions of this technique to measurement lengths well beyond this value,
as long as the issue of relative intensity noise (RIN) of the primary Raman
pump can be avoided.
Ficheros en el ítem
Ficheros | Tamaño | Formato |
|
---|---|---|---|
Brillouin_optical_Opt_Express_ ... | 1.152Mb |
|
Ficheros | Tamaño | Formato |
|
---|---|---|---|
Brillouin_optical_Opt_Express_ ... | 1.152Mb |
|