In-line Mach-Zehnder interferometer based on a dissimilar-doping dual-core fiber for high sensitivity strain and temperature sensing
Identificadores
Enlace permanente (URI): http://hdl.handle.net/10017/27699DOI: 10.1117/12.2059555
ISSN: 0277-786X
ISBN: 978-162841175-1
Editor
Society of Photo-Optical Instrumentation Engineers (SPIE)
Fecha de publicación
2014-06-02Patrocinadores
Ministerio de Economía y Competitividad
European Commission
Comissão Interministerial para a Cooperação
Cita bibliográfica
H, F. Martins ; J. Bierlich ; K. Wondraczek ; S. Unger ; J. Kobelke ; K. Schuster ; M. B. Marques ; M. Gonzalez-Herraez ; O. Frazão;
"In-line Mach-Zehnder interferometer based on a dissimilar-doping dual-core fiber for high sensitivity strain and temperature sensing". Proc. SPIE 9157, 23rd International Conference on Optical Fibre Sensors, 91572C (June 2, 2014)
Palabras clave
Mach–Zehnder interferometer
Optical fiber sensors
Dual-core fiber
Proyectos
info:eu-repo/grantAgreement/CIC//Network Sensing for Critical Systems Monitoring/PT/BESTCASE-RL3-NETSENSING
info:eu-repo/grantAgreement/EC/FP7/307441/EU/Ubiquitous optical FIbre NErves/U-FINE
info:eu-repo/grantAgreement/MINECO//TEC2012-37958-C02-01/ES/TECNOLOGIAS DE SEGURIDAD CIVIL BASADAS EN FIBRA OPTICA/
info:eu-repo/grantAgreement/FCT//SFRH%2FBD%2F76991%2F2011/PT
Tipo de documento
info:eu-repo/semantics/conferenceObject
Versión
info:eu-repo/semantics/acceptedVersion
Versión del editor
http://dx.doi.org/10.1117/12.2059555Derechos de acceso
info:eu-repo/semantics/openAccess
Resumen
A dual-core fiber in which one of the cores is doped with Germanium and the other with Phosphorus is used as an in-line
Mach-Zehnder (MZ) interferometer to perform high sensitivity strain and temperature sensing. Opposite sensitivities for
high and low wavelength peaks were demonstrated when strain was applied. To our knowledge this is the first time that
such behavior is demonstrated using this type of in-line MZ interferometer based on a dual-core fiber. A sensitivity of
(78±2) pm/με, between 0-950 με and (1380±20) pm/ºC between 45 and 80ºC is demonstrated. It was also demonstrated
that it is possible to use this configuration for simultaneous measurement of strain and temperature and a matrix equation
to calculate them was given