Higher incidence pathologies in installations of solar energy, gas, cooling, heating and ventilation
Autores
Carretero Ayuso, Manuel JesúsFecha de publicación
2020-10-20Departamento
Universidad de Alcalá. Departamento de Arquitectura
Patrocinadores
This work was carried out within the Musaat Foundation's Action Plan in line with the "Research Project on pathologies in buildings in Spain".
Cita bibliográfica
Carretero-Ayuso, Manuel J. (2020) “Higher incidence pathologies in installations of solar energy, gas, cooling, heating and ventilation”. XI International Conference on Durability of Building Materials and Components, DBNC 2020, Barcelona.
Palabras clave
Installations
Complaints
Construction Pathologies
Descripción
XV International Conference on Durability of Building Materials and Components (DBMC 2020), 20/10/2020-23/10/2020, Barcelona, España
8 p.
Tipo de documento
info:eu-repo/semantics/conferenceObject
Derechos
Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
Derechos de acceso
info:eu-repo/semantics/openAccess
Resumen
This paper focuses on the study and quantifications of pathologies in solar energy, gas, cooling, heating and ventilation installations, based on complaints filed in the courts by the owners of a large number of houses in which errors appeared in those installations. The relevant complaints filed across all of Spain were studied, in what is an important contribution to forensic engineering, given that access to the outcome of civil court cases is seldom obtained. The representativeness of the data is not partial but total, since the entirety of cases existing in the period under study was part of the sample, enabling us to consider this to be a general exposition on the epidemiology of construction pathologies ins installations in houses in Spain. It should be noted that the Spanish construction sector is one of the most problematic ones, due to the dissatisfaction generated in homeowners, and as it is one of the ones leading to the highest number of complaints filed with consumer protection bureaus and in the courts. In the investigation, results have been obtained for each of the installations (183 cases in total), according to the type of anomaly (the most important are dysfunctions, leaks and humidity), the pathological origin (poorly arranged encounters, omissions of elements, among others) and the type of construction where it is produced (especially in block dwellings).
Ficheros en el ítem
| Ficheros | Tamaño | Formato |
|
|---|---|---|---|
| higher_carretero_DBMC_2020.pdf | 474.4Kb |
|
| Ficheros | Tamaño | Formato |
|
|---|---|---|---|
| higher_carretero_DBMC_2020.pdf | 474.4Kb |
|
Colecciones
- Arquitectura [705]















