Show simple item record

dc.contributor.authorSantiago Rodrigo, Luis de 
dc.contributor.authorFernández Rodríguez, Alfredo José 
dc.contributor.authorBlanco, R.
dc.contributor.authorPérez Rico, María Consuelo 
dc.contributor.authorRodríguez Ascariz, José Manuel 
dc.contributor.authorBarea Navarro, Rafael 
dc.contributor.authorMiguel Jiménez, Juan Manuel 
dc.contributor.authorAmo, C.
dc.contributor.authorSánchez Morla, Eva María 
dc.contributor.authorBoquete Vázquez, Luciano 
dc.date.accessioned2021-07-20T12:17:15Z
dc.date.available2021-07-20T12:17:15Z
dc.date.issued2014-05-07
dc.identifier.bibliographicCitationSantiago, L. de et al. 2014, "Improved measurement of intersession latency in mfVEPs", Documenta Ophthalmologica, vol. 129, no. 1, pp. 65-69.
dc.identifier.issn0012-4486
dc.identifier.urihttp://hdl.handle.net/10017/49178
dc.description.abstractPurpose: The purpose of the study is to present a method (Selfcorr) by which to measure intersession latency differences between multifocal VEP (mfVEP) signals. Methods: The authors compared the intersession latency difference obtained using a correlation method (Selfcorr) against that obtained using a Template method. While the Template method cross-correlates the subject’s signals with a reference database, the Selfcorr method cross-correlates traces across subsequent recordings taken from the same subject. Results: The variation in latency between intersession signals was 0.8 ± 13.6 and 0.5 ± 5.0 ms for the Template and Selfcorr methods, respectively, with a coefficient of variability C V_TEMPLATE = 15.83 and C V_SELFCORR = 5.68 (n = 18, p = 0.0002, Wilcoxon). The number of analyzable sectors with the Template and Selfcorr methods was 36.7 ± 8.5 and 45.3 ± 8.7, respectively (p = 0.0001, paired t test, two tailed). Conclusions: The Selfcorr method produces smaller intersession mfVEP delays and variability over time than the Template method.en
dc.description.sponsorshipMinisterio de Ciencia e Innovaciónes_ES
dc.description.sponsorshipInstituto de Salud Carlos IIIes_ES
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherSpringer
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMultifocal visual-evoked potentialen
dc.subjectRelative latenciesen
dc.subjectCross-correlation
dc.subjectVisual pathwayen
dc.titleImproved measurement of intersession latency in mfVEPsen
dc.typeinfo:eu-repo/semantics/articleen
dc.subject.ecienciaElectrónicaes_ES
dc.subject.ecienciaElectronicsen
dc.contributor.affiliationUniversidad de Alcalá. Departamento de Electrónicaes_ES
dc.relation.publisherversionhttps://doi.org/10.1007/s10633-014-9438-x
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.identifier.doihttps://doi.org/10.1007/s10633-014-9438-x
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//TEC2011-26066/ES/ANALISIS AVANZADO DE LAS SEÑALES DE LOS POTENCIALES EVOCADOS MULTIFOCALES Y DE LA ELECTRORRETINOGRAFIA MULTIFOCAL APLICADOS AL DIAGNOSTICO DE LAS NEUROPATIAS OPTICAS/
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//FIS PI11/00533
dc.relation.projectIDinfo:eu-repo/grantAgreement/ISCIII//RD12%2F0034%2F0006
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen
dc.identifier.publicationtitleDocumenta Ophthalmologica
dc.identifier.publicationvolume129
dc.identifier.publicationlastpage69
dc.identifier.publicationissue1
dc.identifier.publicationfirstpage65


Files in this item

Thumbnail

This item appears in the following Collection(s)

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Este ítem está sujeto a una licencia Creative Commons.