A capillary micellar electrokinetic chromatography method for the stereoselective quantitation of bioallethrin in biotic and abiotic samples
Authors
García González, María ÁngelesIdentifiers
Permanent link (URI): http://hdl.handle.net/10017/48162DOI: 10.1016/j.chroma.2017.06.056
ISSN: 00219673
Date
2017-08-11Academic Departments
Universidad de Alcalá. Departamento de Química Analítica, Química Física e Ingeniería Química
Teaching unit
Unidad docente Química Analítica e Ingeniería Quimica
Funders
Comunidad de Madrid
Ministerio de Economía y Competitividad
Bibliographic citation
Journal of Chromatography A, 2017, v. 1510, p. 108-116
Keywords
Bioallethrin
Capillary electrophoresis
Micellar electrokinetic chromatography
Cyclodextrins
Pyrethroid insecticide
Toxicity
Non-target organism
Project
info:eu-repo/grantAgreement/CAM//S2013%2FMAE-2716/Red Madrileña de Tratamientos Avanzados de Aguas Residuales/REMTAVARES-CM
info:eu-repo/grantAgreement/MINECO//CTQ2013-48740-P/ES/Metodolgoías avanzadas para análisis quiral mediante técnicas microseparativas. Búsqueda de biomarcadores en sistemas enantioselectivos
info:eu-repo/grantAgreement/CAM//S2013%2FABI-3028/ES/Estrategias avanzadas para la mejora y el control de la calidad y la seguridad de los alimentos/AVANSECAL-CM
Document type
info:eu-repo/semantics/article
Version
info:eu-repo/semantics/publishedVersion
Rights
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
© Elsevier
Access rights
info:eu-repo/semantics/openAccess
Abstract
A capillary micellar electrokinetic chromatography (MEKC) method was developed enabling the stereoselective separation of the insecticide bioallethrin. The use of sodium deoxycholate bile salt and acetyl-beta-cyclodextrin (acetyl-beta-CD) made possible the separation of bioallethrin stereoisomers with a high enantioresolution (7.4) in a short analysis time (6.5 min). The analytical characteristics of the developed method were evaluated in terms of linearity, accuracy, precision, and limits of detection (LOD) and quantitation (LOQ) showing a good performance for the quantitation of bioallethrin stereoisomers with LODs of 0.2 and 0.3 mg/L. The developed method was applied to the stereoselective analysis of a commercial bioallethrin pediculicide formulation and to evaluate the toxicity of bioallethrin stereoisomers on the growth of the unicellular freshwater green alga Pseudokirchneriella subcapitata and on the germination of the higher plant Sorghum bicolor (non-target organisms). The analysis of the commercial pediculicide showed a good agreement between the contents determined for the two stereoisomers and those labelled in the commercial samples. Different toxic responses and biodegradation profiles were found for each stereoisomer in ecotoxicity assays. The mixture of SIR stereoisomers of bioallethrin resulted more toxic than S-bioallethrin for green algae, with EC50 values of 1.10 +/- 0.06 for the mixture and of 1.73 +/- 0.05 mg/L for the pure S-biallethrin (esbiol). Germination of plants seeds was also affected. (C) 2017 Elsevier B.V. All rights reserved.