Measuring the human ultra-weak photon emission distribution using an an electron-multiplying, charge-coupled device as a sensor
Authors
Ortega Ojeda, Fernando ErnestoIdentifiers
Permanent link (URI): http://hdl.handle.net/10017/47988DOI: 10.3390/s18041152
ISSN: 1424-8220
Date
2018-04-10Affiliation
Universidad de Alcalá. Departamento de Química Analítica, Química Física e Ingeniería QuímicaFunders
Ministerio de Ciencia, Innovación y Universidades (MICINN).
Bibliographic citation
Sensors, 2018, v. 18, n. 4, p. 1152-1163
Keywords
Ultra-weak photon emission
spectrometer
measurement
electron multiplying charge coupled device sensor
liquid crystal tunable filter.
Project
CTQ2017-91358-EXP (Ministerio de Ciencia, Innovación y Universidades-MICINN). "Explora Ciencia"
Document type
info:eu-repo/semantics/article
Version
info:eu-repo/semantics/publishedVersion
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
MDPI, 2018
Access rights
info:eu-repo/semantics/openAccess
Abstract
Ultra-weak photon emission (UPE) is the spontaneous emission from living systems mainly
attributed to oxidation reactions, in which reactive oxygen species (ROS) may play a major role.
Given the capability of the next-generation electron-multiplying CCD (EMCCD) sensors and the
easy use of liquid crystal tunable filters (LCTF), the aim of this work was to explore the potential
of a simple UPE spectrometer to measure the UPE from a human hand. Thus, an easy setup was
configured based on a dark box for inserting the subject’s hand prior to LCTF as a monochromator
and an EMCCD sensor working in the full vertical binning mode (FVB) as a spectra detector. Under
controlled conditions, both dark signals and left hand UPE were acquired by registering the UPE
intensity at different selected wavelengths (400, 450, 500, 550, 600, 650, and 700 nm) during a period
of 10 min each. Then, spurious signals were filtered out by ignoring the pixels whose values were
clearly outside of the Gaussian distribution, and the dark signal was subtracted from the subject hand
signal. The stepped spectrum with a peak of approximately 880 photons at 500 nm had a shape that
agreed somewhat with previous reports, and agrees with previous UPE research that reported UPE
from 420 to 570 nm, or 260 to 800 nm, with a range from 1 to 1000 photons s-1 cm-2. Obtaining the
spectral distribution instead of the total intensity of the UPE represents a step forward in this field, as
it may provide extra information about a subject’s personal states and relationship with ROS. A new
generation of CCD sensors with lower dark signals, and spectrographs with a more uniform spectral
transmittance, will open up new possibilities for configuring measuring systems in portable formats.
Files in this item
Files | Size | Format |
|
---|---|---|---|
Measuring_Ortega_Sensors_2018.pdf | 5.505Mb |
![]() |
Files | Size | Format |
|
---|---|---|---|
Measuring_Ortega_Sensors_2018.pdf | 5.505Mb |
![]() |
Collections
- QUANING - Artículos [257]