Study on the compressive behaviour of sustainable cement-based composites under one-hour of direct flame exposure
Identifiers
Permanent link (URI): http://hdl.handle.net/10017/46849DOI: 10.3390/su122410548
ISSN: 2071-1050
Date
2020-12-16Academic Departments
Universidad de Alcalá. Departamento de Arquitectura
Funders
This project has received funding from the European Union"s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 754382, GOT ENERGY TALENT
Bibliographic citation
Sustainability, 2020, v. 12, n. 24, p. 10548-
Keywords
Concrete
Cement-based composites (CBCs)
Compressive strength
Fire exposure
Thermal boundaries
Finite element (FE) numerical modelling
Empirical formulations
Project
info:eu-repo/grantAgreement/EC/H2020/754382/EU/GOT Energy Talent
Document type
info:eu-repo/semantics/article
Version
info:eu-repo/semantics/publishedVersion
Rights
Attribution 4.0 International (CC BY 4.0)
(c) MDPI, 2020
Access rights
info:eu-repo/semantics/openAccess
Abstract
Fire is a significant threat to human life and civil infrastructures. Builders and architects are hankering for safer and sustainable alternatives of concrete that do not compromise with their design intent or fire safety requirements. The aim of the present work is to improve the residual compressive performance of concrete in post-fire exposure by incorporating by-products from urban residues.
Based on sustainability and circular economy motivations, the attention is focused on rubber tire fly ash, aged brick powder, and plastic (PET) bottle residuals used as partial sand replacement. The selected by-products from urban residues are used for the preparation of Cement-Based Composites (CBCs) in two different proportions (10% and 15%). Thermal CBC behaviour is thus investigated under realistic fire scenarios (i.e., Direct Flame (DF) for 1 h), by following the International Organization for Standardization (ISO) 834 standard provisions, but necessarily resulting in nonuniform thermal exposure for the cubic specimens. The actual thermal exposure is further explored with a Finite Element (FE) model, giving evidence of thermal boundaries effects. The post-fire residual compressive strength of heated concrete and CBC samples is hence experimentally derived, and compared to
unheated specimens in ambient conditions. From the experimental study, the enhanced post-fire
performance of CBCs with PET bottle residual is generally found superior to other CBCs or concrete.
The structure-property relation is also established, with the support of Scanning Electron Microscopy
(SEM) micrographs. Based on existing empirical models of literature for the prediction of the
compressive or residual compressive strength of standard concrete, newly developed empirical
relations for both concrete and CBCs are assessed.
Files in this item
| Files | Size | Format |
|
|---|---|---|---|
| study_barluenga_SUSTAINABILITY ... | 6.345Mb |
|
| Files | Size | Format |
|
|---|---|---|---|
| study_barluenga_SUSTAINABILITY ... | 6.345Mb |
|
Collections
- Arquitectura [703]
- Horizon 2020 Framework Programme [175]















