Show simple item record

dc.contributor.authorSánchez Prieto, Sebastián 
dc.contributor.authorRegadío Carretero, Alberto 
dc.contributor.authorTabero Godino, Jesús
dc.date.accessioned2019-05-10T17:11:35Z
dc.date.available2019-05-10T17:11:35Z
dc.date.issued2016-03-01
dc.identifier.bibliographicCitationRegadío, A., Tabero, J. & Sánchez-Prieto, S. 2016, "Impact of colored noise in pulse amplitude measurements: a time-domain approach using differintegrals", Nuclear Instruments and Methods in Physics Research Section A, vol. 811, pp. 25-29
dc.identifier.issn0168-9002
dc.identifier.urihttp://hdl.handle.net/10017/37402
dc.description.abstractIn particle detectors, pulse shaping is the process of changing the waveform of the pulses in order to maximize the signal to noise ratio. This shaping usually only takes into account white, pink (flicker) and red (brownian) noise. In this paper, a generalization of noise indexes as a function to an arbitrary f_ noise type, where _ is a real number, is presented. This generalization has been created using the differintegral operator, defined in Fractional Calculus. These formulas are used to calculate the Equivalent Noise Change (ENC) in detector particle systems.en
dc.description.sponsorshipMinisterio de Ciencia e Innovaciónes_ES
dc.description.sponsorshipMinisterio de Economía y Competitividades_ES
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
dc.rights© 2015 Elsevier
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectSpectroscopyen
dc.subjectNoiseen
dc.subjectShapingen
dc.subjectDigital Signal Processingen
dc.subjectResolutionen
dc.titleImpact of colored noise in pulse amplitude measurements: A time-domain approach using differintegralsen
dc.typeinfo:eu-repo/semantics/preprinten
dc.subject.ecienciaTelecomunicacioneses_ES
dc.subject.ecienciaTelecommunicationen
dc.contributor.affiliationUniversidad de Alcalá. Departamento de Automáticaes_ES
dc.date.updated2019-05-10T17:09:34Z
dc.relation.publisherversionhttps://doi.org/10.1016/j.nima.2015.12.010
dc.type.versioninfo:eu-repo/semantics/submittedVersionen
dc.identifier.doi10.1016/j.nima.2015.12.010
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//AYA2011-29727-C02-02/ES/MODULO DE CONTROL PARA EL INSTRUMENTO DE PARTICULAS ENERGETICAS PARA LA MISION SOLAR ORBITER/en
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//AYA2012-39810-C02-02/ES/UNIDAD DE CONTROL PARA EL INSTRUMENTO EPD DE SOLAR ORBITER/en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.identifier.uxxiAR/0000025988
dc.identifier.publicationtitleNuclear Instruments & Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten
dc.identifier.publicationvolume811
dc.identifier.publicationlastpage29
dc.identifier.publicationfirstpage25


Files in this item

Thumbnail

This item appears in the following Collection(s)

Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)