Field testing of a low-cost, self-referenced all-fibre polarimetric current sensor for the monitoring of current in the high-speed railway catenary
Identifiers
Permanent link (URI): http://hdl.handle.net/10017/26506DOI: 10.1117/12.922794
ISSN: 0277-786X
ISSN: 9780819491312
Publisher
Society of Photo Optical Instrumentation Engineers (SPIE)
Date
2012-04-16Funders
Comunidad de Madrid
Bibliographic citation
Filograno, M.L., Corredera, P. & González-Herráez, M. 2012, "Field testing of a low-cost, self-referenced all-fibre polarimetric current sensor for the monitoring of current in the high-speed railway catenary", Belgium , 16-19 April, 2012, Proc. SPIE 8439, Optical Sensing and Detection II, 84391T
Keywords
Faraday Effect
Optical fibre
Current sensor
Polarimetric sensor
High-speed railway
Catenary
Description / Notes
Optical Sensing and Detection II, Brussels, Belgium , 16-19 April, 2012
Project
MIFFO PE IT 77/07 (Ministerio de Fomento)
info:eu-repo/grantAgreement/CAM//S2009%2FESP1781/ES//FACTOTEM2
Document type
info:eu-repo/semantics/conferenceObject
Version
info:eu-repo/semantics/acceptedVersion
Publisher's version
http://dx.doi.org/10.1117/12.922794Rights
Copyright 2013 Society of Photo Optical Instrumentation Engineers
Access rights
info:eu-repo/semantics/openAccess
Abstract
In this paper we present the field testing results of a low-cost all-fibre polarimetric current sensor for the monitoring of current in the European high-speed railway network. The sensor fulfils the requirements of robustness, sensitivity, accuracy and cost required for the monitoring of catenary current in changeover sections. Changeover sections are nonfed sections of the catenary that are placed between sections fed with different phases and that introduce discontinuities in the current collection done by the train. Since the train passes at high-speed between the two sections, an electric arc can be formed that may lead to significant damage of the infrastructure. To avoid this situation, it is essential to ensure the switch-off of the current collection before arriving and switch-on again when the changeover section is passed. An adequate protection system that monitors the current in the catenary before the changeover section allows to trigger the necessary protection mechanisms in the infrastructure. Efficient, robust and lightweight electrical current sensors are therefore essential for this security system. The sensor proposed here uses the Faraday magneto-optic Effect with a well-known polarimetric interrogation method. The optical configuration is extremely simplified through the use of few cost-effective, all-fibre devices with a simplified alignment. It allows high sensitivity for low current values, demonstrating a resolution below the ampere level with a dynamic range up to 500 A. The setup is electronically self-referenced to reduce the effect of small misalignments in the polarization, power variations in the optical source, temperature changes, birefringence effect and bending-induced attenuation in the lead fibre. A set of temperature tests in a climatic chamber were also performed in a range of temperature between -20 up to 80°C, to assess the robustness of the device to operating temperature variations. The field tests include tests during commercial operations and special tests simulating fault conditions.
Files in this item
Files | Size | Format |
|
---|---|---|---|
PP Field testing of a low-cost, ... | 2.547Mb |
![]() |
Files | Size | Format |
|
---|---|---|---|
PP Field testing of a low-cost, ... | 2.547Mb |
![]() |