Show simple item record

dc.contributor.authorGarcía Ruiz, Carmen 
dc.contributor.authorMarina Alegre, María Luisa 
dc.date.accessioned2008-03-03T09:30:00Z
dc.date.available2008-03-03T09:30:00Z
dc.date.issued2006
dc.identifier.bibliographicCitationElectrophoresis, 2006, v. 27, p. 195-212en
dc.identifier.issn0173-0835
dc.identifier.urihttp://hdl.handle.net/10017/1360
dc.description.abstractIn this review, an updated view of the different strategies used up to now to enhance the sensitivity of detection in chiral analysis by CE will be provided to the readers. With this aim, it will include a brief description of the fundamentals and most of the recent applications performed in sensitive chiral analysis by CE using offline and online sample treatment techniques (SPE, liquid-liquid extraction, microdialysis, etc.), on-column preconcentration techniques based on electrophoretic principles (ITP, stacking, and sweeping), and alternative detection systems (spectroscopic, spectrometric, and electrochemical) to the widely used UV-Vis absorption detection.en
dc.description.sponsorshipMinisterio de Ciencia y Tecnologíaes_ES
dc.description.sponsorshipMinisterio de Educación y Cienciaes_ES
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherJohn Wiley & Sonsen
dc.rights(c) Wiley, 2006en
dc.subjectDetection sensitivityen
dc.subjectIsotachophoresisen
dc.subjectOffline and online sample treatment techniquesen
dc.subjectSensitive chiral analysisen
dc.subjectStackingen
dc.titleSensitive chiral analysis by capillary electrophoresis. Reviewen
dc.typeinfo:eu-repo/semantics/articleen
dc.subject.ecienciaCienciaes_ES
dc.subject.ecienciaQuímica analítica e industriales_ES
dc.subject.ecienciaScienceen
dc.subject.ecienciaChemistry, analytic and technicalen
dc.contributor.affiliationUniversidad de Alcalá. Departamento de Química Analítica e Ingeniería Química
dc.relation.publisherversionhttp://dx.doi.org/10.1002/elps.200500418
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.identifier.doi10.1002/elps.200500418
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICYT//BQU2003-03638/ES/CROMATOGRAFÍA ELECTROCINÉTICA: UNA PODEROSA HERRAMIENTA PARA LA SEPARACIÓN ENANTIOMÉRICA DE COMPUESTOS QUIRALES CON APLICACIÓN A LA DETERMINACIÓN DE LA PUREZA ENANTIOMÉRICAes_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MEC//RYC-2003-001/ES/RYC-2003-001/es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen


Files in this item

Thumbnail

This item appears in the following Collection(s)